ABE-IPSABE HOLDINGABE BOOKS
English Polski
Dostęp on-line

Książki

0.00 PLN
Schowek (0) 
Schowek jest pusty
Ferroresonance Oscillations in Substations: with Inductive Voltage Transformers in Medium and High Voltage Systems

Ferroresonance Oscillations in Substations: with Inductive Voltage Transformers in Medium and High Voltage Systems

Autorzy
Wydawnictwo Vde-Verlag
Data wydania 2018
Liczba stron 156
Forma publikacji książka w twardej oprawie
Język angielski
ISBN 9783800733958
Kategorie Wytwarzanie energii i dystrybucja
Zapytaj o ten produkt
E-mail
Pytanie
 
Do schowka

Opis książki

The motivation for this book was the increase in the appearance of ferroresonance oscillation in substations. The price pressure on the operating authorities and as well on component manufacturers i.e. for instrument transformer, power transformer and grading capacitors for high-performance circuit breakers has led to gradually increasing demands on power system and components.In the IEC Dictionary the following definition can be found for ferroresonance: "a resonance of the capacitance of an apparatus with the inductance of saturable magnetic circuit of an adjacent apparatus".Ferroresonance refers to non-linear oscillations that can occur in power systems where inductive components with a ferromagnetic core, together with capacitances and an AC voltage source comprise a system capable of oscillation.In contrast to a linear resonant circuit, a circuit with non-linear inductance exhibits no well-defined resonance frequency. A sinusoidal source voltage of a fixed frequency can excite different frequencies (harmonic and subharmonic frequencies). In addition, the amplitude of the excited oscillations is not limited only by the power loss in the resonant circuit. For each oscillation mode, a resultant oscillation amplitude can be found.This book provides an overview of the undesired phenomenon of ferroresonance oscillations in high and medium voltage networks in connection with the inductive voltage transformers (VT). Ferroresonance oscillations can cause considerable damage to the VT and neighboured equipment. Because of the various forms of manifestation, cases of ferroresonance are not always recognized as such.The book is addressed to designers and operators of high voltage power installations and manufacturers of inductive voltage transformers.

Ferroresonance Oscillations in Substations: with Inductive Voltage Transformers in Medium and High Voltage Systems

Polecamy również książki

Strony www Białystok Warszawa
801 777 223